Guide · 6 minute read · England
Building regs for windows and doors Part L, F, B and K on one page
A builder's checklist for replacement windows and doors in England. The four parts that matter: Part L (U-values), Part F (trickle vents), Part B (escape windows) and Part K (safety glass), and which box to tick on our job sheet for each.
- Replacement windows
- 1.4 W/m²K or WER band B
- Escape window
- 0.33 m², 450 × 450 mm
- Safety glass
- Class 3, BS EN 12600
- Applies to
- England only
Part L
Part L: U-values for replacement windows and doors
For replacement windows in an existing dwelling in England, Part L sets a limit of 1.4 W/m²K (U-value of the whole window) or Window Energy Rating (WER) band B as a minimum. The replacement should also be no worse than the window it replaces. The figure is for the complete window as supplied, not for the frame profile.
| Case | Limit | Note |
|---|---|---|
| Replacement windows, existing dwelling | 1.4 W/m²K, or WER band B minimum | The window as a whole, at its own size |
| Replacement doors, more than 60% of internal face glazed | 1.4 W/m²K, or Doorset Energy Rating (DER) band C | Check the glazed share per door |
| Other replacement doors | 1.4 W/m²K, or DER band B | |
| Windows in an extension | Same as replacement windows (1.4 or WER band B) | Follows the existing-dwelling column |
| Windows in a new dwelling, limiting value | 1.6 W/m²K | Limiting value only: the whole-house calculation usually asks for better |
| Doors in a new dwelling, including glazed doors | 1.6 W/m²K | Same note as windows |
Source: Approved Document L Vol 1, 2021 edition incl. 2023 amendments, Tables 4.1 and 4.2; gov.uk publication page
Four things that catch people out
- Leaflet figures are not compliance figures. A system maker's "Uw from" value is for a reference window under set conditions. Compliance is shown for the real window, by a calculated U-value or a WER from a certified rating scheme. Building control may accept a rating with a quality-assured audit trail.
- Thicker glass still has to meet the limit. If safety or security needs thicker glass, the U-value must still be met by an equivalent unit made with standard 6 mm glazing.
- Enlarging an opening. If you make a window bigger or add a new one, total glazing should not go over 25% of the floor area unless it is compensated elsewhere.
- Listed or character buildings. Where the character of the building stops you reaching 1.4, the guidance allows a centre-pane U-value of 1.2 W/m²K or less, or single glazing with low-e secondary glazing. Agree it with building control first.
2026 edition. The 2026 edition of Approved Document L has been published. It takes effect on 24 March 2027 (24 September 2027 for higher-risk buildings). The replacement window limit is unchanged at 1.4 W/m²K or WER band B. Until then the 2021 edition with 2023 amendments applies.
Parts F and B
Trickle vents and escape windows: Part F and Part B
Part F: trickle vents (background ventilators)
- Old windows had vents: fit vents in the new ones that are not smaller than the originals, controllable by the occupant or automatically.
- Old windows had none: ventilation must be no worse than before. One accepted route is vents of at least 8000 mm² equivalent area in each habitable room, 8000 mm² in the kitchen and 4000 mm² in a bathroom. With continuous mechanical extract fitted, 4000 mm² per habitable room.
- Size of the old vents unknown: the sizes above can be used.
- Equivalent area, not free area. The number on the vent's data sheet must be the equivalent area. A vent with a bigger free area can have a smaller equivalent area.
- Height: where possible, vents sit at least 1700 mm above floor level.
Source: Approved Document F Vol 1, paras 1.15, 1.34, 3.14 and 3.15; gov.uk publication page
Part B: escape windows
A window that serves as an escape route (usually in a first-floor bedroom) needs an unobstructed openable area that meets all of these:
- at least 0.33 m² openable area;
- at least 450 mm high and 450 mm wide (the route can be at an angle);
- the bottom of the openable area no more than 1100 mm above the floor;
- the window stays open without being held. Locks and child-resistant opening stays are allowed.
Replacing an existing escape window: the new window should give at least the same potential for escape. If the old opening was larger than the minimum above, it can be reduced to that minimum.
The clear opening is measured on the finished window, with the sash open on its stay or hinge, not on the frame size. On outward casements the hinge type changes the clear opening, which is why bedroom windows are often specified with fire-escape (egress) hinges. Check the actual clear opening of each window against the figures above before you order.
Source: Approved Document B Vol 1, paras 2.10, 2.18 to 2.20 and 3.6
Part K
Safety glass in critical locations: Part K
Glass in "critical locations" must break safely, or be robust, or be in small panes, or be permanently protected. The critical locations are shown in Diagram 5.1 of Approved Document K. In short:
- In doors and side panels: glazing between the floor and 1500 mm.
- In windows: glazing within 800 mm of the floor.
Check the diagram for the exact zones beside doors on your job.
| Where | Class needed | Standard |
|---|---|---|
| Critical location, general | Class 3 | BS EN 12600 (or Class C of BS 6206) |
| Door or side panel wider than 900 mm | Class 2 is enough | BS EN 12600 (or Class B of BS 6206) |
Source: Approved Document K, section 5 and Diagram 5.1; gov.uk publication page
Most builders meet this with toughened or laminated safety glass in the low panes, patio and French doors, and glazed side panels. Tell us which panes, and tick the box on the job sheet.
Job sheet
On the job sheet, tick...
You do not need to work out the vent size or the hinge on the sketch. Tick the box, write the room on the frame, and we price it in.
| If the job has... | Rule | Tick this box |
|---|---|---|
| Old windows with vents, or a room that needs ventilation added | Part F: vents no smaller than the originals, or 8000 mm² equivalent area per habitable room | Trickle vents |
| A bedroom window above ground floor that is the escape route | Part B: 0.33 m², 450 × 450 mm, bottom at most 1100 mm, stays open | Fire-escape hinges |
| Glass within 800 mm of the floor, or in a door or side panel below 1500 mm | Part K: Class 3 of BS EN 12600 (Class 2 in a door or side panel over 900 mm wide) | Toughened safety glass |
| A bathroom or other room needing privacy | Not a Part L, F, B or K rule: a privacy choice | Obscure glass |
| Any replacement window or door | Part L: 1.4 W/m²K or WER band B for windows; compliance shown per window | No box: tell us before you order |
Obscure glass in a critical location still has to meet Part K, so tick both where a bathroom window is low.
This guide is a summary, not legal advice. It covers England only. Wales and Scotland have their own rules. Building control has the final say on your job, so confirm anything doubtful with them before you order.
Send
What to send for a price
Send the sketch as in our sketching guide: sizes in mm viewed from outside, which panes open and the hinge side, colour, glazing, opening direction. Then add the regs extras:
- The room on each frame, so we can see where escape windows and obscure glass go.
- The ticks above: trickle vents, fire-escape hinges, toughened safety glass, obscure glass.
- If the old windows had vents, the old vent size, or say it is unknown.
- Anything building control has asked for in writing.
Send a job or start with aluminium windows. Then see the aluminium windows and uPVC windows pages for the systems.
Questions
Questions builders ask
What U-value do replacement windows need in England?
1.4 W/m²K for the whole window, or Window Energy Rating band B as a minimum, under Approved Document L. Doors with more than 60% of the inside face glazed can use 1.4 or Doorset Energy Rating band C; other doors 1.4 or band B.
Do replacement windows need trickle vents?
If the old windows had them, the new ones need vents no smaller than the originals. If the old ones had none, ventilation must be no worse than before. One route is 8000 mm² equivalent area per habitable room. It is equivalent area that counts, not free area.
Which windows must be fire-escape windows?
Windows that serve as the escape route, typically first-floor bedrooms. They need at least 0.33 m² openable area, at least 450 mm high and wide, a bottom edge no higher than 1100 mm, and must stay open unaided. Measure the finished clear opening.
Does glass in a bathroom window have to be toughened?
Only if it is in a critical location, which means within 800 mm of the floor for a window. Obscure glass is a privacy choice, not a safety rule, so a low obscure pane needs both.
Has the 2026 edition of Approved Document L changed the limits for replacement windows?
The 2026 edition takes effect on 24 March 2027 (24 September 2027 for higher-risk buildings). The replacement window limit is unchanged: 1.4 W/m²K or WER band B. Check the transitional rules with building control for jobs that straddle the date.
Do these rules apply in Wales and Scotland?
No. This guide covers England. Wales and Scotland have their own building regulations, so check the local rules before you specify.