- Home
- Entrance doors
Product · Entrance doors
Aluminium front doors made to your survey sizes
Aluminium front doors on Aluprof MB-79N, MB-86N and Reynaers MasterLine 8, with side lights and top lights, opening in or out. Send a photo of your sketch with the hinge side viewed from outside. You get a trade price, delivered, back in one working day.
A front door sketch we can priceAll sizes in mm
- Systems
- Aluprof MB-79N, MB-86N, Reynaers MasterLine 8
- Price back in
- One working day
- Price includes
- Delivery to yard or site
- Trade only
- No homeowner quotes
Systems
Aluminium front doors compared
Aluminium front doors are built on the same systems as our windows, so the frame and the colour match. Pick by the leaf size you need and the security the job asks for.
| Aluprof MB-79N | Aluprof MB-86N | Reynaers MasterLine 8 | |
|---|---|---|---|
| Frame / leaf depth | 70 / 70 mm | 77 / 77 mm | 77 / 77 mm |
| Largest leaf (H × W) | 2800 × 1400 mm | 3000 × 1400 mm | 3000 × 1400 mm, up to 250 kg |
| Best published Ud | From 0.90 (SI+, 1400 × 2800, Ug 0.5) | From 0.80 (SI+, 1400 × 3000, Ug 0.5) | 0.98 (single inward door 1.23 × 2.18 m, Ug 0.6). Uf 1.3 |
| Opening | Single and double external doors, inward or outward by door type | Single and double doors, inward and outward | Data given for a single inward door |
| Glass thickness | 1.5 to 54 mm | Not stated for doors | Not stated |
| Security, as stated | RC1 to RC3 | Aluprof: anti-burglary windows and doors up to RC4. SKG-tested for 1 million cycles | RC2, RC3 and PAS 24 (Reynaers). 1,000,000 cycles |
| Weather | Water tightness E900, wind class C5/B5 | Water tightness E1350, wind class C5/B5 | Water tightness 8A, wind class C2 |
| Other | Zero-threshold variants. Automation and access-control hardware available | Inward and outward doors | Sightlines: inward frame 68.5 mm, leaf 78.5 mm, frame plus leaf 153 mm |
Source: Aluprof MB-79N leaflet (EN-06.2025); Aluprof MB-86N leaflet (EN-06.2025); Reynaers MasterLine 8 door technical info
Uf is the frame figure; Ud is the whole door. A leaflet "Uw from" figure is a best case for one size, one glass and one thermal variant. It is not a compliance figure for your window. Part L compliance is shown for each window, by a calculated U-value or a Window Energy Rating.
Layout
Side lights, top lights and which way it opens
Side lights and top lights are fixed panes next to or above the door, usually in the same frame. Draw them on the sketch with their widths and heights, and say which are glass and which are solid panels.
Hinge side: hinged left means the hinges are on your left as you stand outside facing the door. This is the handing that goes wrong most often, so write it on the sketch.
In or out: most UK front doors open inward, but MB-86N and MB-79N doors can open outward. Say which you want and give the frame size, not just the leaf size.
For level access, MB-79N has zero-threshold variants. Tell us if the job needs one.
Regs
Part L door limits and glazing safety
- Replacement doors, existing dwelling: 1.4 W/m²K, or a Doorset Energy Rating band: band C for doors with more than 60% of the internal face glazed, band B for other doors (ADL 2021 incl. 2023 amendments, Table 4.2).
- New dwellings: the limiting U-value for doors, including glazed doors, is 1.6 W/m²K (Table 4.1).
- Part K: glass in doors and side panels is in a critical location, so side lights next to a door are covered too. Class 3 of BS EN 12600, or Class 2 in a door or side panel wider than 900 mm (ADK, Section 5).
- Proof: compliance is shown for each door, by a calculated U-value or Doorset Energy Rating. A system's "Ud from" is not a compliance figure.
See the building regulations guide.
Price
What to send for an entrance doors price
Use the job sheet and attach the sketch. See how to sketch for a quote.
- Sizes: overall frame width × height in mm, and the width of the door leaf, side light and top light.
- Hinge side: left or right, viewed from outside.
- Opening: in or out.
- Glass and panels: which parts are glass, which are solid, and any obscure or toughened glass.
- Colour: outside and inside, as a RAL number.
- Security and extras: any RC or PAS 24 requirement, level threshold, and any door furniture or access control to price.
uPVC front and back doors are also available. See uPVC windows and doors.
Questions
Questions builders ask
Can I get a PAS 24 aluminium front door?
Reynaers states PAS 24 for the MasterLine 8 door, along with RC2 and RC3. Aluprof states RC classes for its doors, for example RC1 to RC3 for MB-79N. If the job needs PAS 24, say so on the job sheet and we confirm the system before you order.
What U-value do aluminium front doors reach?
Aluprof publishes Ud from 0.90 for MB-79N (SI+, 1400 × 2800 mm, Ug 0.5) and from 0.80 for MB-86N (SI+, 1400 × 3000 mm, Ug 0.5). Reynaers gives 0.98 for MasterLine 8 (single inward door, Ug 0.6). These are best cases. A real door needs its own calculation or Doorset Energy Rating.
What is the largest door leaf?
MB-79N: 2800 × 1400 mm. MB-86N and MasterLine 8: 3000 × 1400 mm (H × W). For MasterLine 8 the leaf can weigh up to 250 kg.
Which side is the hinge on?
Say it viewed from outside. Hinged left means the hinges are on your left as you face the door from outside. Mark it with a triangle pointing to the hinge side.
Do you do side lights and top lights?
Yes, as fixed panes in the same frame as the door. Draw them on the sketch with their sizes, and say if each is glass or solid.
Does a glazed front door need safety glass?
Yes. Glass in doors and side panels is a critical location under Part K. It needs Class 3 of BS EN 12600, or Class 2 in a door or side panel wider than 900 mm.
Send the sketch. We'll do the pricing.
Photo of the sketch, four ticks, your postcode. Trade price with delivery within one working day.