Send a job
  1. Home
  2. Aluminium windows

Product · Aluminium windows

Aluminium windows for the trade made to your survey sizes

Aluminium windows in tilt-and-turn or outward-opening casement, on Aluprof MB-79N, MB-86N or Reynaers MasterLine 8. Send a photo of your sketch and four ticks. You get a trade price, delivered to yard or site, back in one working day.

Tilt-and-turn, as you would sketch itAll sizes in mm

Aluminium window sketch, tilt-and-turn and fixedA two-pane window 1500 millimetres wide and 1400 high, viewed from outside. The left pane is tilt-and-turn, hinged on the left, shown by a turn triangle pointing left and a tilt triangle pointing down. The right pane is fixed.VIEWED FROM OUTSIDE15001400LEFT: TILT-AND-TURN, HINGED LEFT · RIGHT: FIXED
1500 × 1400 · left sash tilt-and-turn, hinged left · right fixed · viewed from outside
Systems
Aluprof MB-79N, MB-86N, Reynaers MasterLine 8
Price back in
One working day
Price includes
Delivery to yard or site
Trade only
No homeowner quotes

Systems

Aluminium window systems compared

We supply aluminium windows on three system families: Aluprof MB-79N, Aluprof MB-86N and Reynaers MasterLine 8. Each has a tilt-and-turn version, and MB-79N and MB-86N also have an outward-opening casement version. Pick by opening type, size and the performance the job needs. If you are unsure, send the sketch and say what the building needs.

Aluminium window systems: published data
MB-79NMB-79N CasementMB-86NMB-86 CasementMasterLine 8
Frame / sash depth70 / 79 mm70 / 79 mm77 / 86 mm77 / 86 mm77 / 87 mm
Best published UwFrom 0.64 (SI, fixed, 1700 × 2700, Ug 0.5). Openable from 0.72 (1700 × 2150)From 0.74 (SI, openable, 1900 × 2500, Ug 0.5)From 0.62 (SI, fixed, 1700 × 2800, Ug 0.5). Openable from 0.68 (1700 × 2150)Not quotedUw 0.88 (Ug 0.6, 1.23 × 1.48 m, 36 mm glass). Uf 1.0
Largest sash (H × W)2700 × 1350 mm, or 2150 × 1700 mm2700 × 1400 mm, or 2500 × 2400 mm. Vent up to 180 kg3000 × 1700 mm2500 × 2400 mm, or 2800 × 1400 mmNot published by Reynaers for windows
Opening typesFixed, turn, tilt, tilt-and-turn, tilt-and-slideOutward-opening. Concealed scissor or visible pivot hingesFixed, side-hung, hopper, tilt-and-turnOutward-opening: fixed, side-hung, top-hungInward- and outward-opening versions
Glass thickness in sash10.5 to 63 mm10.5 to 63 mm17.5 to 70 mm22 to 70 mm13 to 72 mm
Security, as statedDoors RC1 to RC3. No window class in the leafletNot statedAluprof: anti-burglary windows and doors up to RC4Not statedRC2, RC3 and PAS 24 (Reynaers)

Source: Aluprof MB-79N leaflet (EN-06.2025); Aluprof MB-79N Casement card; Aluprof MB-86N leaflet (EN-06.2025); Aluprof MB-86 Casement; Reynaers MasterLine 8 technical info

Air permeability is class 4 (EN 12207, the top class) on MB-79N, MB-79N Casement, MB-86N and MasterLine 8. A leaflet "Uw from" figure is a best case for one size, one glass and one thermal variant. It is not a compliance figure for your window. Part L compliance is shown for each window, by a calculated U-value or a Window Energy Rating. The Uw figures above were measured under different conditions, so do not read them as a ranking of real windows.

Opening

Tilt-and-turn or outward casement?

Tilt-and-turn windows open inward: tilted at the top for ventilation, or swung in on side hinges for cleaning and escape. Outward casements open like the older timber windows many UK installers know. Both are available in aluminium here: the casements are the MB-79N Casement and the MB-86 Casement.

Tilt-and-turn needs clear space inside the room, and curtains and blinds need thought. An outward casement needs the hinges and stays to suit the finish outside. Neither is a regulatory requirement. Our tilt-and-turn vs casement guide goes through the trade-offs. Mark it on the job sheet and we price it your way.

Regs

Building regs for replacement aluminium windows

These are the rules that most often change a replacement window order in England. Wales and Scotland have their own rules. The building regulations guide covers them in full.

  • Part L, heat loss: replacement windows in an existing dwelling need a U-value of 1.4 W/m²K or Window Energy Rating band B (ADL 2021 incl. 2023 amendments, Table 4.2). New dwellings have a limiting value of 1.6 W/m²K for windows (Table 4.1).
  • Part F, trickle vents: if the old windows had background ventilators, the new ones need ventilators at least as big. If they had none, one route is ventilators of 8000 mm² equivalent area in each habitable room and the kitchen, and 4000 mm² in a bathroom. Equivalent area counts, not free area (ADF paras 3.14 and 3.15).
  • Part B, escape windows: where a window is an escape window it needs an unobstructed openable area of at least 0.33 m², at least 450 mm high and 450 mm wide, with the bottom of the opening no more than 1100 mm above the floor, and it must stay open without being held (ADB Vol 1, para 2.10). Replacing a window that was big enough for escape should give at least the same potential for escape (paras 2.18 to 2.20).
  • Part K, glazing safety: glass in a window within 800 mm of the floor is in a critical location and needs safety glazing, Class 3 of BS EN 12600 (ADK, Section 5).

Tick escape windows, trickle vents and low panes on the job sheet and they are priced in.

Price

What to send for an aluminium windows price

Send the sketch with the four ticks and these details. Use the job sheet, and see how to sketch for a quote if you want a checklist.

  • Sizes: width × height in mm for every frame, viewed from outside. Say if they are frame sizes or opening sizes.
  • Opening: which panes open, hinge side viewed from outside, and whether each opens in (tilt-and-turn) or out (casement).
  • Colour: outside and inside, as a RAL number.
  • Glazing: double or triple.
  • Extras: trickle vents, escape windows, obscure or toughened panes, bays and couplings, and the room each frame is in.

We make every frame to your final survey sizes, so survey properly before you order.

Questions

Questions builders ask

What is the U-value of MB-79N windows?

Aluprof publishes "Uw from 0.64" for a fixed SI window of 1700 × 2700 mm with Ug 0.5 glass, and from 0.72 for an openable window of 1700 × 2150 mm. That is a best case, not a figure for your window. For replacement windows in England you need a calculated U-value of 1.4 W/m²K or better for the actual window, or a Window Energy Rating of band B or better.

Do replacement aluminium windows need trickle vents?

If the old windows had trickle vents, the new ones need vents no smaller. If they had none, the ventilation must be no worse than before, and one way to show that is 8000 mm² equivalent area in each habitable room and the kitchen, 4000 mm² in a bathroom (Approved Document F). Say on the job sheet which applies.

Tilt-and-turn or casement for a replacement job?

Casements open outward and look like the older windows. Tilt-and-turn opens inward and cleans from inside. Both come in aluminium. See the comparison guide, then tick your choice on the job sheet.

Can I get triple glazing?

Yes. Tick triple on the job sheet. Sash glass thickness runs to 63 mm on MB-79N, 70 mm on MB-86N and 72 mm on MasterLine 8 (makers' published ranges).

Do you fit the windows?

No. We supply made to measure and deliver to your yard or site. You survey and fit, and every frame is made to your survey sizes.

What is the largest window you can supply?

It depends on the system and how the sash opens. The table shows the published sash maxima. Send the size you need and say which panes open, and we say whether it works or should be split with a mullion.

Send the sketch. We'll do the pricing.

Photo of the sketch, four ticks, your postcode. Trade price with delivery within one working day.

Send a job