Product · Aluminium bifold doors

Aluminium bifold doors priced from your sketch

Aluminium bifold doors on the Aluprof MB-86 Fold Line HD, with up to 8 panels, opening in or out, made to your survey sizes. Send a photo of your sketch with the stacking side and the number of panels. You get a trade price, delivered, back in one working day.

A bifold sketch we can priceAll sizes in mm

Bifold door sketch, four panels, three fold leftA four-panel bifold door 3600 millimetres wide and 2100 high, viewed from outside. Each panel is 900 wide. Panels one to three fold to the left. The fourth panel on the right is a single traffic door hinged on its right side, shown by a triangle pointing right.VIEWED FROM OUTSIDE36002100PANELS 1 TO 3 FOLD LEFT3+1 · SINGLE PANEL HINGED RIGHT (TRAFFIC DOOR)
3600 × 2100 · four 900 mm panels · 3+1, three fold left, right panel is a hinged traffic door · viewed from outside
System
Aluprof MB-86 Fold Line HD
Price back in
One working day
Price includes
Delivery to yard or site
Trade only
No homeowner quotes

Spec

Aluminium bifold doors: MB-86 Fold Line HD

Our aluminium bifold doors are Aluprof MB-86 Fold Line HD. Panels hinge together and fold away to one or both sides. The system opens outward or inward, so you choose whether the panels stack outside or inside the room.

Aluprof MB-86 Fold Line HD: published data
ItemValue
PanelsUp to 8, in corner or panoramic layouts. Panels can be configured as wanted
Panel width700 to 1200 mm
Panel heightUp to 3000 mm
Panel weightUp to 120 kg per panel
Opening directionOutwards or inwards
DepthFrame 86 mm, panels 77 mm
Thermal breakThree-cavity profiles, thermal break 24 mm in the frame and 34 mm in the panels
Glass thickness13.5 to 61.5 mm, double or triple. Acoustic and burglary-resistant glass possible
ThresholdsWeather-bar threshold, or low threshold
SecurityNo class stated. Burglary-resistant glass can be fitted

Source: Aluprof MB-86 Fold Line HD leaflet (EN-06.2022); Aluprof MB-86 Fold Line HD

The system shares profiles, gaskets and accessories with MB-86N. We do not quote a leaflet Uw for the bifold: the real value depends on the width, height and glass. For Part L, see below. More on the system: Aluprof MB-86 Fold Line HD.

Stacking

Which way do bifold doors stack?

Panels fold like a concertina and stack to one side, or half to each side. Always give the stacking side viewed from outside: "stacks left" means left as you stand outside looking at the building. This is the first thing that goes wrong on a bifold order.

Opening direction also matters. If the panels open outward, they fold onto the outside and leave the room clear. If they open inward, they stack inside the room and need space for it. Check the floor, the furniture and any blinds before you choose.

Layouts are written as panels folding left plus panels folding right. For example:

  • 4+0: all four panels stack on one side.
  • 2+2: two stack left, two stack right, meeting in the middle.
  • 3+1: three stack on one side, and the single panel at the other end works as a door.

Layout

Odd or even panels, and the traffic door

A traffic door is a single panel hinged to the frame that opens like an ordinary door. You walk through it without opening the whole set. It is the usual way to get everyday access from a bifold.

Panels fold in pairs, so an even number can all fold away. An odd number leaves one panel over, and that panel can work as the traffic door. Mark on the sketch which panel is the traffic door and which side it is hinged, viewed from outside.

If you want no traffic door, say so. Tell us the total width and the number of panels you want, or the panel width, and we work out the rest. Panels are 700 to 1200 mm wide, so a very wide opening needs more panels, up to 8.

Regs

Part L and glazing safety on bifold doors

  • Part L, replacement: doors in an existing dwelling need 1.4 W/m²K or a Doorset Energy Rating band. A bifold is normally more than 60% glazed on its internal face, so the band is C (ADL 2021 incl. 2023 amendments, Table 4.2).
  • Part L, new dwellings: the limiting U-value for doors, including glazed doors, is 1.6 W/m²K (Table 4.1).
  • Part K: glass in doors and side panels is in a critical location. It needs Class 3 of BS EN 12600, or Class 2 in a door or side panel wider than 900 mm (ADK, Section 5). Panels here run from 700 to 1200 mm, so check each width.
  • Evidence: compliance is shown for the door, by a calculated U-value or Doorset Energy Rating. A system leaflet figure is not enough.

See the building regulations guide.

Price

What to send for an aluminium bifold doors price

Use the job sheet and attach the sketch. See how to sketch for a quote.

  • Opening size: width × height in mm, viewed from outside, and whether it is a frame size or an opening size.
  • Panels: how many, and the layout, for example 3+1.
  • Stacking side: left or right, viewed from outside.
  • Traffic door: yes or no, which panel, and its hinge side.
  • Opening direction: panels open in or out.
  • Colour and glazing: outside and inside colour, double or triple, and any safety, acoustic or burglary-resistant glass.
  • Threshold: weather-bar or low.

Questions

Questions builders ask

How many panels can an aluminium bifold door have?

The Aluprof MB-86 Fold Line HD takes up to 8 panels. Each panel is 700 to 1200 mm wide, up to 3000 mm high, and up to 120 kg.

Do bifold doors open in or out?

Either on this system. Outward panels fold onto the outside and keep the room clear. Inward panels stack inside the room. Say which on the job sheet.

What is a traffic door on a bifold?

A single panel hinged to the frame that opens like a normal door, so you can walk through without opening the whole bifold. An odd number of panels lets one panel work this way.

How do I say which way the doors stack?

Left or right, viewed from outside, and write the layout as panels folding left plus panels folding right, for example 3+1. Draw an arrow on the sketch to show the stack.

What U-value do aluminium bifold doors achieve?

It depends on size and glass, so we do not quote a leaflet figure. For Part L in England, a replacement bifold needs 1.4 W/m²K or Doorset Energy Rating band C, because a bifold is normally more than 60% glazed. Tell us if building control wants a calculated value.

Does the glass need to be toughened?

Glass in doors and side panels is a critical location under Part K. It needs Class 3 of BS EN 12600, or Class 2 in a door or side panel wider than 900 mm. Toughened or laminated glass is the usual way to do it.