System · Bifold doors
Aluprof MB-86 Fold Line HD aluminium bifold doors, trade price from your sketch
Aluprof MB-86 Fold Line HD is a thermally broken aluminium bifold door system. It takes up to 8 panels, each up to 3000 mm high and 700 to 1200 mm wide, and it opens inward or outward. Send the opening size and how you want the panels to stack, and we price it made to measure, for trade only.
- Panels
- Up to 8
- Panel size
- To 3000 mm high, 700 to 1200 mm wide
- Panel weight
- Up to 120 kg
- Opens
- Inward or outward
Specs
Aluprof MB-86 Fold Line HD specification
The system shares profiles, gaskets and accessories with MB-86N, so a job with MB-86N windows and a bifold can match in frame depth and look. Figures are Aluprof's.
| Item | Detail |
|---|---|
| Depth | Frame 86 mm. Panels 77 mm. |
| Thermal break | 3-cavity profiles. Thermal break 24 mm in the frame and 34 mm in the panels. |
| Number of panels | Up to 8. Corner and panoramic layouts are available, with panels set out as you want them. |
| Panel size | Height up to 3000 mm. Width 700 to 1200 mm. |
| Panel weight | Up to 120 kg per panel. |
| Opening direction | Outward or inward. |
| Glass thickness | 13.5 to 61.5 mm, double or triple. Acoustic and burglary-resistant glass can be fitted. |
| Thresholds | Weather-bar threshold and low threshold variants. |
| Security | Aluprof does not state a security class for the system. |
Source: Aluprof MB-86 Fold Line HD leaflet (EN-06.2022), Aluprof MB-86 Fold Line HD page
Fit for the job
Where Fold Line HD suits, and where it does not
Good for
- Wide openings onto a garden or terrace that must open almost fully, in extensions and new builds.
- Corner and panoramic layouts, where two folding runs meet.
- Jobs where the bifold should match MB-86N windows and doors in depth and finish.
Not for
- Very large single panes with few joints. A lift-and-slide door gives fewer frames in the view.
- Jobs that need a stated PAS 24 or RC class on the bifold. Aluprof gives none for this system.
- Level-threshold access that must be fully flush. Aluprof lists a weather-bar and a low threshold, so say what access you need and we check it against the variants.
- Tight rooms where the folded stack or an outward-opening leaf would hit something. Mark the stacking side on the sketch.
See the bifold doors overview or compare on the systems page.
Part L and Part K
Bifold doors, Part L and safety glass
A leaflet figure such as "Uw from" is a result for one test size and one glass specification. It is not a compliance figure for a real bifold door. In England, a replacement window in an existing dwelling needs a U-value of 1.4 W/m²K or Window Energy Rating Band B or better (Approved Document L, 2021 edition incorporating 2023 amendments, Table 4.2). New dwellings have a limiting value of 1.6 W/m²K for windows (Table 4.1). Compliance is shown for each window, using its real size, glass and spacer, by calculation or by an energy rating.
Aluprof's leaflet gives no headline Uw for Fold Line HD, because the figure depends on the number and size of panels and the glass. Replacement doors in an existing dwelling need 1.4 W/m²K or a Doorset Energy Rating, Band C if more than 60% of the inner face is glazed. Glass in doors and side panels is a critical location under Part K: it must be safety glass, normally Class 3 to BS EN 12600, or Class 2 in a door or side panel wider than 900 mm.
Wales and Scotland have their own rules. Check with your building control body what evidence they want, and say on the job sheet if the job needs it. More on trickle vents, escape windows and safety glass in the building regulations guide.
Get a price
What to send for a bifold door price
Send a hand sketch and four ticks and we come back with a trade price, delivered to yard or site. Every order is made to your survey sizes, so survey properly before you order. You fit.
- Overall opening width and height, number of panels, and which way the stack folds (left, right, or split), viewed from outside.
- One traffic door or none, and whether the panels open in or out.
- A photo of your sketch with width × height in mm on every frame, drawn as seen from outside.
- Which panes open and which side they are hinged. Mark fixed panes as fixed.
- Colour outside and inside (RAL number or foil name), and double or triple glazing.
- Opening direction: outward like a UK casement, or inward tilt-and-turn.
- Anything the regs need: escape windows, obscure or toughened glass, trickle vents, a U-value or energy rating.
Send a job for a price or read how to sketch for a quote. Product overview: bifold doors.
Questions
Questions builders ask
How many panels can MB-86 Fold Line HD have?
Up to 8 panels, with corner or panoramic layouts, each up to 3000 mm high and 700 to 1200 mm wide. Send the opening width and we suggest a panel count that keeps each panel inside the 1200 mm limit.
What is the U-value of MB-86 Fold Line HD?
Aluprof's leaflet gives no headline Uw for this system. The result depends on the number and size of panels, the glass and the spacer, so we cannot quote a single figure. For Part L, the whole door needs a calculated U-value or a Doorset Energy Rating.
How heavy is each bifold panel?
Aluprof gives a maximum panel weight of 120 kg. The glass thickness (13.5 to 61.5 mm) and panel size set the actual weight.
Do the doors open in or out?
Both are listed: Fold Line HD opens outward or inward. Tick your choice on the job sheet.
Can the glass be safety or burglary-resistant glass?
Yes. Aluprof says acoustic and burglary-resistant glass can be fitted. Doors need safety glass under Part K anyway, so say on the job sheet that the panels are doors and the safety glass is priced in.
Send the sketch. We'll do the pricing.
Photo of the sketch, four ticks, your postcode. Trade price with delivery within one working day.