Send a job
  1. Home
  2. Systems
  3. Aluprof MB-79N

System · Aluminium windows and doors

Aluprof MB-79N aluminium windows and doors, trade price from your sketch

Aluprof MB-79N is a thermally broken aluminium system with a 70 mm frame and a 79 mm vent for windows. Aluprof quotes Uw from 0.72 W/m²K for an opening window with Ug 0.5 triple glazing. There is also an outward-opening MB-79N Casement and a matching 70 mm door. Send a sketch and we price it made to measure, for trade only.

Depth
70 mm frame, 79 mm vent
Uw from
0.72 opening, Ug 0.5
Max vent H × L
2700 × 1350 mm
Opens
Turn, tilt-turn, tilt-slide

Specs

Aluprof MB-79N specification

MB-79N is the series to look at when you want a slim aluminium window and door in one matching 70 mm profile. The figures below are Aluprof's, with the conditions they were measured under.

Aluprof MB-79N, windows and doors
ItemDetail
Frame and vent depthFrame 70 mm. Window vent 79 mm. Door leaf 70 mm.
VariantsWindows E, ST and SI. Doors ST, SI and SI+. Thermal breaks of an insulating material let the seal sit in the insulation zone.
Best Uw, fixed windowFrom 0.64 W/m²K: SI variant, fixed window 1700 × 2700 mm, Ug 0.5.
Best Uw, opening windowFrom 0.72 W/m²K: opening window 1700 × 2150 mm, Ug 0.5.
Best Ud, doorFrom 0.90 W/m²K: SI+ door 1400 × 2800 mm, Ug 0.5.
Example Uw, SI window0.70 at Ug 0.5, 0.86 at Ug 0.7, 1.13 at Ug 1.0 (Multitech frame, double-chamber scheme).
Example Uw, ST window0.82 at Ug 0.5, 0.98 at Ug 0.7, 1.25 at Ug 1.0.
Glass thicknessWindow: fixed 1.5 to 54 mm, vent 10.5 to 63 mm (double or triple). Door: 1.5 to 54 mm.
Maximum size (H × L)Window vent to 2700 × 1350 mm or 2150 × 1700 mm. Door leaf to 2800 × 1400 mm.
Opening typesWindows: fixed, turn, tilt, tilt-and-turn, tilt-and-slide. Doors: single and double, inward or outward depending on the door type.
SecurityDoors RC1 to RC3. Windows RC2 and RC3 are available.
PerformanceAir permeability class 4. Water tightness E1950 (windows), E900 (doors). Wind load C5 (windows), C5 and B5 (doors).
Doors, otherZero-threshold door variants are available (to DIN 18040).

Source: Aluprof MB-79N leaflet (EN-06.2025), Aluprof MB-79N product page

MB-79N Casement: the outward-opening version

Casements are the usual UK window style, and MB-79N Casement is the version of the system that opens outward. Same 70 mm frame and 79 mm vent, with a thermal break 36 and 35 mm wide. It takes concealed scissor hinges or visible pivot hinges.

Aluprof MB-79N Casement
ItemDetail
Best UwFrom 0.74 W/m²K: SI variant, opening window 1900 × 2500 mm, Ug 0.5.
Maximum vent (H × L)2700 × 1400 mm or 2500 × 2400 mm (leaflet EN-06.2025).
Maximum vent weight180 kg, per Aluprof's casement product card.
Glass thicknessFrame 1.5 to 54 mm, vent 10.5 to 63 mm.
Smallest operable ventFrom 270 mm.
Variants and performanceVariants E, ST and SI. Air class 4, water tightness E1800, wind load C5 and B5.

Source: Aluprof MB-79N leaflet (EN-06.2025), Aluprof MB-79N Casement page, Aluprof MB-79N Casement product card

Fit for the job

Where MB-79N suits, and where it does not

Good for

  • Replacement aluminium windows in houses and flats where you want a slim frame and a matching entrance door in the same profile.
  • Outward-opening casements in terraces and period-style fronts, using the MB-79N Casement version.
  • Tilt-and-turn windows where you want to clean from inside, often the lower price.
  • Mixed jobs: windows, a front door and a rear door from one system.

Not for

  • Very tall or wide single sashes beyond the limits above. For taller windows look at MB-86N, which Aluprof lists to 3000 mm high.
  • Sliding patio doors or bifolds. Use MB-77HS or MB-86 Fold Line HD.
  • Jobs that specify PAS 24 or Secured by Design. Aluprof states RC classes, not PAS 24. If the spec needs PAS 24, see Reynaers MasterLine 8, where the maker states it.

Compare all seven on the systems page, or see the aluminium windows overview.

Part L

MB-79N U-value and Part L

A leaflet figure such as "Uw from" is a result for one test size and one glass specification. It is not a compliance figure for a real MB-79N window or door. In England, a replacement window in an existing dwelling needs a U-value of 1.4 W/m²K or Window Energy Rating Band B or better (Approved Document L, 2021 edition incorporating 2023 amendments, Table 4.2). New dwellings have a limiting value of 1.6 W/m²K for windows (Table 4.1). Compliance is shown for each window, using its real size, glass and spacer, by calculation or by an energy rating.

For doors in existing dwellings the limit is also 1.4 W/m²K, or a Doorset Energy Rating of Band C where more than 60% of the inner face is glazed, otherwise Band B.

Wales and Scotland have their own rules. Check with your building control body what evidence they want, and say on the job sheet if the job needs it. More on trickle vents, escape windows and safety glass in the building regulations guide.

Get a price

What to send for an MB-79N price

Send a hand sketch and four ticks and we come back with a trade price, delivered to yard or site. Every order is made to your survey sizes, so survey properly before you order. You fit.

  • Say if you want the MB-79N Casement (outward) or standard MB-79N (usually tilt-and-turn).
  • A photo of your sketch with width × height in mm on every frame, drawn as seen from outside.
  • Which panes open and which side they are hinged. Mark fixed panes as fixed.
  • Colour outside and inside (RAL number or foil name), and double or triple glazing.
  • Opening direction: outward like a UK casement, or inward tilt-and-turn.
  • Anything the regs need: escape windows, obscure or toughened glass, trickle vents, a U-value or energy rating.

Send a job for a price or read how to sketch for a quote. Product overview: aluminium windows.

Questions

Questions builders ask

What is the U-value of MB-79N?

Aluprof quotes Uw from 0.64 W/m²K for a fixed window (1700 × 2700 mm, Ug 0.5) and from 0.72 for an opening window (1700 × 2150 mm, Ug 0.5). With Ug 0.7 glass the SI example is 0.86, and with Ug 1.0 it is 1.13. These are leaflet values for set sizes. The U-value of your window depends on its size, glass and spacer, and is what Part L looks at.

Is MB-79N available as an outward-opening casement?

Yes. MB-79N Casement uses the same 70 mm frame and 79 mm vent and opens outward, with concealed scissor hinges or visible pivot hinges. Aluprof gives Uw from 0.74 W/m²K for an opening window of 1900 × 2500 mm with Ug 0.5. Tick "outward" on the job sheet.

What glass thickness does MB-79N take?

Aluprof lists 1.5 to 54 mm for the fixed frame and 10.5 to 63 mm for the opening vent, so double or triple glazing. Doors take 1.5 to 54 mm.

How big can an MB-79N window or door be?

Aluprof gives a maximum window vent of 2700 × 1350 mm or 2150 × 1700 mm (height × length), and a door leaf up to 2800 × 1400 mm. The casement version goes to 2700 × 1400 mm or 2500 × 2400 mm. Send the sizes and we check them.

Can I use MB-79N for entrance doors?

Yes. The door leaf is 70 mm, with Aluprof Ud from 0.90 W/m²K (SI+, 1400 × 2800 mm, Ug 0.5), security up to RC3 and zero-threshold variants. See also entrance doors.

MB-79N or MB-86N?

MB-86N is the deeper system, with a 77 mm frame and 86 mm vent, and Aluprof lists lower Uw figures and taller windows for it. MB-79N is slimmer. If the job is a normal replacement, MB-79N usually does it. See MB-86N.

Send the sketch. We'll do the pricing.

Photo of the sketch, four ticks, your postcode. Trade price with delivery within one working day.

Send a job