Guide · Measuring
Opening size to frame size measuring for supply-only windows
On a supply-only order the sizes come from you, and the frames are made to them. This is how to get from the brick opening to a frame size that fits first time, and how big a gap to leave around it.
- Measure
- Three widths, three heights
- Use
- The smallest of each
- Typical gap, aluminium
- 5 mm per side up to 3 m wide
- Who is responsible
- The buyer, on the confirmed checklist
Measure
Measure the opening, not the old window
- Width at three points: top, middle and bottom of the opening, brick to brick.
- Height at three points: left, centre and right, from the sill or threshold line to the head.
- Take the smallest width and the smallest height. Openings are rarely square, and the frame has to fit the tightest point.
- Check the diagonals. If they differ by more than a few millimetres, the opening is out of square; note it on the sketch.
- Write down which size you are sending: the structural opening or the frame size. Say it on the sketch. Most remakes start here.
Gap
How big a gap to leave
The frame is made smaller than the opening, so it can be packed, fixed and sealed. Warranty providers publish recommended gaps per side. The table below is the one used by Premier Guarantee and LABC Warranty.
| Frame material | Opening under 1.5 m | 1.5 to 3.0 m | 3.0 to 4.5 m |
|---|---|---|---|
| Aluminium | 5 mm | 5 mm | 7.5 mm |
| uPVC, white | 5 mm | 5 mm | 7.5 mm |
| uPVC, coloured or foiled | 7.5 mm | 7.5 mm | 11 mm |
| Timber | 5 mm | 5 mm | 5 mm |
The same guidance caps the gap at 10 mm for openings under 3 m and 15 mm over 3 m. Gaps over 5 mm need a backing rod behind the sealant. Source: LABC Warranty, gaps around windows. Your warranty provider or the job's specification can ask for something different; follow that if it does.
Example
Worked example
| Step | Figure |
|---|---|
| Smallest opening width | 1215 mm |
| Smallest opening height | 1210 mm |
| Aluminium, under 1.5 m: 5 mm each side | minus 10 mm on width, 10 mm on height |
| Frame size to send | 1205 × 1200 mm |
If a sill or a cill extension sits under the frame, take its height off the frame height as well, and say so on the sketch.
Before you confirm
Before you confirm the order
- Every size on the order checklist matches your survey sheet, frame size or opening size as you stated.
- Opening sashes are drawn as seen from outside, with the hinge side.
- Safety glass and obscure glass are marked where you need them; the rules are in building regs for windows and doors.
- Trickle vents are ticked where Part F asks for them.
Sizes are yours: we make exactly what you confirmed on the order checklist. If something on the checklist does not match your survey, change it before you confirm; after that, the frames go into production.
FAQ
Questions builders ask
Should I send the opening size or the frame size?
Either, as long as you say which. If you send the opening size and ask us to take the fitting gap off, write that on the sketch and we show the resulting frame size on the checklist for you to confirm.
How much smaller than the opening should the frame be?
For aluminium, warranty guidance used by Premier Guarantee and LABC Warranty gives 5 mm per side for openings up to 3 m wide and 7.5 mm from 3 to 4.5 m. Check what your warranty provider or specification asks for.
Who pays if a window is the wrong size?
Sizes are the buyer's responsibility. We make exactly what was confirmed on the order checklist, so check every line against your survey before you confirm.
Can I quote from a photo and measure later?